NTX Series Nanofiltration Membrane Elements
|
Introduction |
BHM, is attached to the Global 500 enterprise CHEMCHINA. BHM adjusted the formula of membrane-making liquid to improve the rejection performance and selective permeability and realize the effective desalination and concentration to sulfate solution system.
|
Membrane element performance |
|
Model |
NTX-8040-28i |
NTX-8040-34i |
NTX-4040 |
|
|
Rejection rate (%) |
NaCl |
50-85 |
||
|
MgSO4 |
99 |
|||
|
Permeate flow m3/d(gpd) |
38(10,000) |
34(9,000) |
8.5(2,250) |
|
|
Width of inlet conduit(mil) |
28 |
34 |
34 |
|
Note: The final stable rejection rate after testing 30 minutes as the standard rejection rate; the fluctuation range of permeate flow is 15%
|
Testing conditions |
|
Pressure (Mpa/psi) |
0.75/110 |
|
Inflow concentration(NaCl) mg/L |
2000±50 |
|
Inflow concentration(MgSO4) mg/L |
2000±50 |
|
Temperature(゜C) |
25.0±1 |
|
PH value |
7-8 |
|
Recovery rate (%) |
15±1 |
|
Maximum operating conditions |
|
Pressure (Mpa/psi) |
4.1/600 |
|
Temperature(゜C) |
40 |
|
Inflow SDI |
5 |
|
Residual chlorine concentration of inlet water(mg/L) |
0.1 |
|
Inflow PH range during continuously operating |
3-10 |
|
Inflow PH range during chemical cleaning |
2-11 |
|
Max. pressure loss of single membrane element (Mpa/psi) |
0.10/15 |
Hot Tags: ntx series nanofiltration membrane elements, China, manufacturers, suppliers, factory, buy, price